Your Good Partner in Biology Research

Human oxidized low density lipoprotein,OxLDL ELISA Kit

  • 中文名称:
    人氧化低密度脂蛋白(OxLDL)酶联免疫试剂盒
  • 货号:
    CSB-E07931h
  • 规格:
    96T/48T
  • 价格:
    ¥3600/¥2500
  • 其他:

产品详情

  • 产品描述:
    CUSABIO人氧化低密度脂蛋白(OxLDL)酶联免疫试剂盒(货号:CSB-E07931h),采用竞争法定量原理设计,可精准检测血清、血浆、尿液、唾液、组织匀浆及细胞裂解液等多种样本中OxLDL水平,其检测线性范围覆盖1.56至100 mU/mL,适用于低浓度样本的科研分析。试剂盒基于生物素标记的特异性抗体与样本中的OxLDL竞争结合预包被抗原,通过HRP标记的链霉亲和素系统显色,吸光度值与OxLDL浓度呈负相关,从而实现定量检测。该产品经过严格的性能验证,样本前处理步骤已优化适配不同基质,实验流程可在4.5小时内完成。OxLDL作为低密度脂蛋白的氧化修饰形式,是动脉粥样硬化斑块形成的关键生物标志物,参与炎症反应和血管内皮损伤机制研究。本试剂盒可应用于心血管疾病基础研究、氧化应激相关代谢机制探索、药物或天然产物抗氧化效价评估等科研领域,为体外实验提供高灵敏度的检测方案,但不适用于临床诊断。
  • 缩写:
    OxLDL
  • 种属:
    Homo sapiens (Human)
  • 样本类型:
    serum, plasma, urine, saliva, tissue homogenates, cell lysates
  • 检测范围:
    1.56 mU/mL-100 mU/mL
  • 灵敏度:
    0.78 mU/mL
  • 反应时间:
    1-5h
  • 样本体积:
    50-100ul
  • 检测波长:
    450 nm
  • 研究领域:
    Others
  • 测定原理:
    quantitative
  • 测定方法:
    Competitive
  • 精密度:
    Intra-assay Precision (Precision within an assay): CV%<8%      
    Three samples of known concentration were tested twenty times on one plate to assess.  
    Inter-assay Precision (Precision between assays): CV%<10%      
    Three samples of known concentration were tested in twenty assays to assess.    
                 
  • 线性度:
    To assess the linearity of the assay, samples were spiked with high concentrations of human OxLDL in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.
      Sample Serum(n=4)  
    1:100 Average % 99  
    Range % 93-105  
    1:200 Average % 94  
    Range % 91-98  
    1:400 Average % 103  
    Range % 99-107  
    1:800 Average % 86  
    Range % 80-92  
  • 回收率:
    The recovery of human OxLDL spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.
    Sample Type Average % Recovery Range  
    Serum (n=5) 98 94-104  
    EDTA plasma (n=4) 94 88-97  
                 
                 
  • 标准曲线:
    These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.
    mU/ml OD1 OD2 Average    
    100 0.130 0.129 0.130    
    50 0.306 0.301 0.304    
    25 0.549 0.557 0.553    
    12.5 0.941 0.956 0.949    
    6.25 1.401 1.418 1.410    
    3.12 1.953 1.967 1.960    
    1.56 2.186 2.087 2.137    
    0 2.758 2.656 2.707    