中文名称:大鼠血纤蛋白原降解产物(FDP)酶联免疫试剂盒
-
货号:CSB-E07942r
-
规格:96T/48T
-
价格:¥3900/¥2500
-
其他:
产品详情
-
产品描述:CUSABIO专为大鼠样本设计的血纤蛋白原降解产物(FDP)定量检测试剂盒,采用双抗体夹心ELISA原理,适用于血清、血浆及组织匀浆样本的科研分析。FDP是纤维蛋白原在纤溶酶作用下的降解产物,其浓度变化可反映机体纤溶系统活性,常用于评估凝血功能异常、血栓性疾病或炎症反应相关研究。试剂盒检测范围为15.6-1000 ng/mL,实验操作中需使用50μL标准品或样本,通过链霉亲和素-HRP系统显色后在450nm波长下测定吸光度值。产品包含预包被96孔板、标准品、检测抗体、显色底物及终止液等完整组分,可在4-8°C保存6个月,避免反复冻融。该试剂盒适用于心血管疾病模型、肝纤维化研究或创伤修复实验中纤溶系统功能的动态监测,为探究凝血与纤溶平衡机制提供高灵敏度的定量工具,实验结果需结合专业分析软件进行标准曲线拟合计算。
-
别名:N/A
-
缩写:FDP
-
种属:Rattus norvegicus (Rat)
-
样本类型:serum, plasma, tissue homogenates
-
检测范围:15.6 ng/mL-1000 ng/mL
-
灵敏度:3.9 ng/mL
-
反应时间:1-5h
-
样本体积:50-100ul
-
检测波长:450 nm
-
研究领域:Others
-
测定原理:quantitative
-
测定方法:Sandwich
-
精密度:
Intra-assay Precision (Precision within an assay): CV%<8% Three samples of known concentration were tested twenty times on one plate to assess. Inter-assay Precision (Precision between assays): CV%<10% Three samples of known concentration were tested in twenty assays to assess. -
线性度:
To assess the linearity of the assay, samples were spiked with high concentrations of rat FDP in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. Sample Serum(n=4) 1:1 Average % 97 Range % 93-102 1:2 Average % 90 Range % 85-94 1:4 Average % 95 Range % 91-99 1:8 Average % 85 Range % 81-92 -
回收率:
The recovery of rat FDP spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. Sample Type Average % Recovery Range Serum (n=5) 92 88-96 EDTA plasma (n=4) 105 99-109 -
标准曲线:
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. ng/ml OD1 OD2 Average Corrected 1000 2.305 2.251 2.278 2.091 500 1.711 1.641 1.676 1.489 250 1.203 1.221 1.212 1.025 125 0.793 0.815 0.804 0.617 62.5 0.529 0.566 0.548 0.361 31.25 0.467 0.441 0.454 0.267 15.6 0.264 0.247 0.256 0.069 0 0.193 0.181 0.187 -
数据处理:
-
货期:3-5 working days
引用文献
- Dehydroepiandrosterone (DHEA) Improves the Metabolic and Haemostatic Disturbances in Rats with Male Hypogonadism SM Safwat,Multidisciplinary Digital Publishing Institute,2022
- Mesopore Controls the Responses of Blood Clot‐Immune Complex via Modulating Fibrin Network S Wu,Advanced science (Weinheim, Baden-Wurttemberg, Germany),2021
- Swim exercise inhibits hemostatic abnormalities in a rat model of obesity and insulin resistance Dallak M.et al,Arch Physiol Biochem,2018
- Swimming, but not vitamin E, ameliorates prothrombotic state and hypofibrinolysis in a rat model of nonalcoholic fatty liver disease Sakr HF.et al,J Basic Clin Physiol Pharmacol,2017
- Triclosan causes spontaneous abortion accompanied by decline of estrogen sulfotransferase activity in humans and mice Wang X. et al,Sci Rep,2015
- Antithrombin III/SerpinC1 insufficiency exacerbates renal ischemia/reperfusion injury Wang F. et al,Kidney Int,2015
- (2-Hydroxypropyl)-ß-Cyclodextrin Is a New Angiogenic Molecule for Therapeutic Angiogenesis Xun Qi, et al,PLoS One,2015
- Effects of warfarin and l-carnitine on hemostatic function and oxidative stress in streptozotocin-induced diabetic rats Elgendy AA et al,J Physiol Biochem,2014
相关产品
Most popular with customers
-
Human Transforming Growth factor β1,TGF-β1 ELISA kit
Detect Range: 23.5 pg/ml-1500 pg/ml
Sensitivity: 5.8 pg/ml
-
-
-
Mouse Tumor necrosis factor α,TNF-α ELISA Kit
Detect Range: 7.8 pg/ml-500 pg/ml
Sensitivity: 1.95 pg/ml
-
-
-
-