中文名称:大鼠高密度脂蛋白胆固醇酶联免疫试剂盒
-
货号:CSB-E14399r
-
规格:96T/48T
-
价格:¥3600/¥2500
-
其他:
产品详情
-
产品描述:大鼠高密度脂蛋白胆固醇酶联免疫试剂盒(CSB-E14399r)为双抗夹心法ELISA试剂盒,定量检测血清、血浆、组织匀浆样本中的HDL-C含量。HDL - C即高密度脂蛋白胆固醇,它被视作“好胆固醇”,背景上与心血管健康密切相关,较高水平的HDL - C有助于降低心血管疾病风险。其研究机制主要是促进胆固醇逆向转运,将外周组织中的胆固醇转运到肝脏进行代谢,减少胆固醇沉积。试剂盒检测范围为93.75 ng/mL-6000 ng/mL,适用于动脉粥样硬化发病机制研究、脂代谢调控实验、药物干预效果评价等科研领域,可支持动物模型构建、营养学实验及心血管相关分子通路的探索。本品仅用于科研,不用于临床诊断,产品具体参数及操作步骤详见产品说明书。
-
缩写:HDL-C
-
种属:Rattus norvegicus (Rat)
-
样本类型:serum, plasma, tissue homogenates
-
检测范围:93.75 ng/mL-6000 ng/mL
-
灵敏度:23.4 ng/mL
-
反应时间:1-5h
-
样本体积:50-100ul
-
检测波长:450 nm
-
研究领域:Others
-
测定原理:quantitative
-
测定方法:Sandwich
-
精密度:
Intra-assay Precision (Precision within an assay): CV%<8% Three samples of known concentration were tested twenty times on one plate to assess. Inter-assay Precision (Precision between assays): CV%<10% Three samples of known concentration were tested in twenty assays to assess. -
线性度:
To assess the linearity of the assay, samples were spiked with high concentrations of rat HDL-C in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. Sample Serum(n=4) 1:200 Average % 87 Range % 83-89 1:400 Average % 99 Range % 95-102 1:800 Average % 90 Range % 85-93 1:1600 Average % 99 Range % 92-102 -
回收率:
The recovery of rat HDL-C spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. Sample Type Average % Recovery Range Serum (n=5) 94 89-97 EDTA plasma (n=4) 107 101-109 -
标准曲线:
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. ng/ml OD1 OD2 Average Corrected 6000 2.612 2.554 2.583 2.483 3000 2.122 2.158 2.140 2.040 1500 1.449 1.453 1.451 1.351 750 0.845 0.831 0.838 0.738 375 0.420 0.434 0.427 0.327 187.5 0.272 0.278 0.275 0.175 93.75 0.176 0.169 0.173 0.073 0 0.101 0.099 0.100 -
数据处理:
-
货期:3-5 working days
引用文献
- Ethanolic Extract of Orange Leaves Ameliorates Dyslipidemia in Streptozotocin-induced Diabetic Rats. N Dodantenna,/,2024
- Effect of n-3 PUFA supplementation at different EPA: DHA ratios on the spontaneously hypertensive obese rat model of the metabolic syndrome Molinar-Toribio E et al,Br J Nutr,2015