中文名称:人blca-4酶联免疫试剂盒
-
货号:CSB-E14959h
-
规格:96T/48T
-
价格:¥3600/¥2500
-
其他:
产品详情
-
产品描述:CUSABIO人BLCA-4酶联免疫检测试剂盒(货号:CSB-E14959h),采用双抗体夹心法定量检测血清、血浆、尿液及组织匀浆样本中膀胱癌特异性生物标志物BLCA-4的水平。BLCA-4是一种与膀胱癌发生密切相关的核基质蛋白,其异常表达可作为膀胱癌早期研究的重要分子靶点。试剂盒检测灵敏度为0.625 ng/mL,线性范围覆盖0.625-40 ng/mL,预包被高特异性抗体可确保检测的特异性,实验过程包含标准品孵育、样本反应、显色及终止步骤,总耗时约4小时。适用于科研领域中对膀胱癌发病机制、肿瘤微环境调控及生物标志物筛查的研究,支持多种生物样本类型的平行检测,为体外实验提供稳定可靠的定量分析工具。试剂盒包含预装微孔板、标准品、检测抗体及全套实验试剂,操作便捷且重复性良好。
-
缩写:BLCA-4
-
种属:Homo sapiens (Human)
-
样本类型:serum, plasma, urine, tissue homogenates
-
检测范围:0.625 ng/mL-40 ng/mL
-
灵敏度:0.156 ng/mL
-
反应时间:1-5h
-
样本体积:50-100ul
-
检测波长:450 nm
-
研究领域:Others
-
测定原理:quantitative
-
测定方法:Sandwich
-
精密度:
Intra-assay Precision (Precision within an assay): CV%<8% Three samples of known concentration were tested twenty times on one plate to assess. Inter-assay Precision (Precision between assays): CV%<10% Three samples of known concentration were tested in twenty assays to assess. -
线性度:
To assess the linearity of the assay, samples were spiked with high concentrations of human blca-4 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. Sample Serum(n=4) 1:1 Average % 87 Range % 84-91 1:2 Average % 99 Range % 96-103 1:4 Average % 104 Range % 101-107 1:8 Average % 95 Range % 89-99 -
回收率:
The recovery of human blca-4 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. Sample Type Average % Recovery Range Serum (n=5) 87 84-90 EDTA plasma (n=4) 92 88-96 -
标准曲线:
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. ng/ml OD1 OD2 Average Corrected 40 2.595 2.540 2.568 2.452 20 2.208 2.365 2.287 2.171 10 1.823 1.804 1.814 1.698 5 1.195 1.175 1.185 1.069 2.5 0.698 0.678 0.688 0.572 1.25 0.418 0.432 0.425 0.309 0.625 0.271 0.276 0.274 0.158 0 0.115 0.117 0.116 -
数据处理:
-
货期:3-5 working days
引用文献
- Methods for the surveillance, diagnosis and screening of bladder cancer Jean-Pierre Roperch , et al,/,2019
- Bladder cancer specific nuclear matrix proteins -4 maybe a potential biomarker for non muscle-invasive bladder cancer detection Zhi-Yong Wang.et al,/,/
- The Diagnostic Value of Nuclear Matrix Proteins in Bladder Cancer in the Aspect of Environmental Risk from Carcinogens. Beata SzymaNska.et al,BioMed Research International,2017
相关问答
I am interested in purchasing the kit for a study that we wanted to perform. Can you please tell me more abou the antibodies that comprise this kit?
CSB-E14959h The kit uses double antibody sandwich method to quatitative detect blca-4.
And its coated antibody is goat polyclonal antibody, biotin-conjugated antibody (that is, detection antibody) is goat polyclonal antibody
As for the specific components of the kit can be seen in the manual MATERIALS PROVIDED part.I will send the manual to you by e-mail. Pls let me know if you have any further questions. Thank you.
Most popular with customers
-
Human Transforming Growth factor β1,TGF-β1 ELISA kit
Detect Range: 23.5 pg/ml-1500 pg/ml
Sensitivity: 5.8 pg/ml
-
-
-
Mouse Tumor necrosis factor α,TNF-α ELISA Kit
Detect Range: 7.8 pg/ml-500 pg/ml
Sensitivity: 1.95 pg/ml
-
-
-
-