中文名称:人8异前列腺素F2α(8-iso-PGF2a)酶联免疫试剂盒
-
货号:CSB-E12100h
-
规格:96T/48T
-
价格:¥3600/¥2500
-
其他:
产品详情
-
产品描述:CUSABIO人8异前列腺素F2α(8-iso-PGF2α)酶联免疫试剂盒(货号:CSB-E12100h),专为定量检测血清、血浆样本中8-iso-PGF2α水平而设计。8-iso-PGF2α是脂质过氧化反应的稳定代谢产物,作为氧化应激的生物标志物,广泛参与炎症反应、心血管疾病及代谢紊乱等病理过程的研究。试剂盒基于竞争法原理,通过特异性抗体与样本中的目标分子结合实现检测,其灵敏度覆盖125 pg/mL至5000 pg/mL的线性范围,能够满足不同浓度样本的精准分析需求。该试剂盒操作流程简便,仅需常规实验室设备即可完成,样本无需复杂前处理,适用于细胞氧化损伤机制研究、抗氧化药物筛选评价以及环境或营养因素对机体氧化应激影响的科学探索。通过标准化实验方案和高品质预包被板设计,确保实验结果的重复性和可靠性,为氧化应激相关领域的基础研究与转化医学提供高效检测工具。
-
别名:8-iso prostaglandin F2α,8-iso prostaglandin F2 alpha,8-iso-PGF2α,8-iso-PGF2 alpha
-
缩写:8-iso-PGF2a
-
种属:Homo sapiens (Human)
-
样本类型:serum, plasma
-
检测范围:125 pg/mL-5000 pg/mL
-
灵敏度:125 pg/mL
-
反应时间:1-5h
-
样本体积:50-100ul
-
检测波长:450 nm
-
研究领域:Others
-
测定原理:quantitative
-
测定方法:Competitive
-
精密度:
Intra-assay Precision (Precision within an assay): CV%<15% Three samples of known concentration were tested twenty times on one plate to assess. Inter-assay Precision (Precision between assays): CV%<15% Three samples of known concentration were tested in twenty assays to assess. -
线性度:
To assess the linearity of the assay, samples were spiked with high concentrations of human 8-iso-PGF2a in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. Sample Serum(n=4) 1:1 Average % 96 Range % 90-100 1:2 Average % 92 Range % 85-99 1:4 Average % 95 Range % 90-103 1:8 Average % 94 Range % 90-99 -
回收率:
The recovery of human 8-iso-PGF2a spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. Sample Type Average % Recovery Range Serum (n=5) 95 88-102 EDTA plasma (n=4) 97 91-103 -
标准曲线:
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. pg/ml OD1 OD2 Average 5000 0.124 0.126 0.125 2500 0.219 0.232 0.226 1150 0.341 0.354 0.348 375 0.605 0.646 0.626 125 1.273 1.305 1.289 0 2.654 2.551 2.603 -
数据处理:
-
货期:3-5 working days
引用文献
- Blood cadmium concentration and pulmonary function injury: potential mediating role of oxidative stress in chronic obstructive pulmonary disease patients J Xu, FM Zhu, Y Liu, P Fang, J Sun, MY Liu,BMC Pulmonary Medicine,2024
- Association between blood arsenic concentration and dyslipidemia: Mediating effect of lipid peroxidation in the elderly JH Huang,Journal of trace elements in medicine and biology,2023
- Arsenic exposure and lung function decline in chronic obstructive pulmonary disease patients: The mediating influence of systematic inflammation and oxidative stress YF Liu,Food and chemical toxicology,2023
- Cobalt exposure and dyslipidemia in elderly population: the mediating role of systemic inflammation and lipid peroxidation JH Huang,Environmental science and pollution research international,2023
- Decreased plasma neuregulin 4 levels are associated with peripheral neuropathy in Chinese patients with newly diagnosed type 2 diabetes: A cross-sectional study Yan P.et al,Cytokine,2018
- EFEK INTERVENSI BUAH TAKOKAK (Solanum torvum Swartz) TERHADAP KADAR SUPEROKSIDA DISMUTASE ERITROSIT DAN 8-ISOPROSTAN SERUM PADA Putri Novitasari.et al,Jurnal Gizi dan Pangan,2016
- Bioprospecting the Curculigoside-Cinnamic Acid-Rich Fraction from Molineria latifolia Rhizome as a Potential Antioxidant Therapeutic Agent Ooi DJ.et al,Molecules.,2016
Most popular with customers
-
Human Transforming Growth factor β1,TGF-β1 ELISA kit
Detect Range: 23.5 pg/ml-1500 pg/ml
Sensitivity: 5.8 pg/ml
-
-
-
Mouse Tumor necrosis factor α,TNF-α ELISA Kit
Detect Range: 7.8 pg/ml-500 pg/ml
Sensitivity: 1.95 pg/ml
-
-
-
-