中文名称:人2,3-二磷酸甘油酸(2,3-DPG)酶联免疫试剂盒
-
货号:CSB-E09861h
-
规格:96T/48T
-
价格:¥3600/¥2500
-
其他:
产品详情
-
产品描述:CUSABIO定量检测人血清、血浆、组织匀浆及细胞裂解液中2,3-二磷酸甘油酸(2,3-DPG)含量的酶联免疫试剂盒,采用双抗体夹心法原理进行精准检测。2,3-DPG是红细胞糖酵解的重要中间产物,通过调控血红蛋白与氧气的亲和力,在组织氧释放和缺氧适应中发挥关键作用。试剂盒检测范围为0.312-20 μmol/mL,可灵敏识别样本中微量2,3-DPG的存在,适用于基础研究中红细胞代谢功能评估、缺氧生理机制探索以及血液系统疾病模型的机制分析,例如贫血、高原反应或心血管相关疾病的体外实验研究。试剂盒提供预包被抗体板及标准品,操作流程标准化,仅需100 μL样本即可完成检测,配套试剂经过严格验证,具备良好的批间一致性和稳定性,满足细胞能量代谢、运动生理学或病理状态下的氧运输调控等科研需求。建议使用新鲜样本进行检测,避免反复冻融影响检测精度。
-
缩写:2,3DPG
-
种属:Homo sapiens (Human)
-
样本类型:serum, plasma, tissue homogenates, cell lysates
-
检测范围:0.312 μmol/mL-20 μmol/mL
-
灵敏度:0.078 μmol/mL
-
反应时间:1-5h
-
样本体积:50-100ul
-
检测波长:450 nm
-
研究领域:Others
-
测定原理:quantitative
-
测定方法:Sandwich
-
精密度:
Intra-assay Precision (Precision within an assay): CV%<8% Three samples of known concentration were tested twenty times on one plate to assess. Inter-assay Precision (Precision between assays): CV%<10% Three samples of known concentration were tested in twenty assays to assess. -
线性度:
To assess the linearity of the assay, samples were spiked with high concentrations of human 2, 3-DPG in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. Sample Serum(n=4) 1:1 Average % 96 Range % 92-100 1:2 Average % 98 Range % 92-103 1:4 Average % 95 Range % 90-99 1:8 Average % 90 Range % 85-96 -
回收率:
The recovery of human 2, 3-DPG spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. Sample Type Average % Recovery Range Serum (n=5) 89 85-94 EDTA plasma (n=4) 84 80-89 -
标准曲线:
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. µmol/ml OD1 OD2 Average Corrected 20 2.873 2.712 2.793 2.636 10 2.265 2.149 2.207 2.050 5 1.372 1.328 1.350 1.193 2.5 0.854 0.813 0.834 0.677 1.25 0.457 0.481 0.469 0.312 0.625 0.337 0.357 0.347 0.190 0.312 0.202 0.207 0.205 0.048 0 0.161 0.152 0.157 -
数据处理:
-
货期:3-5 working days
引用文献
- AVALIAÇÃO DA EFICÁCIA DE SUPLEMENTAÇÃO DE CONCENTRADOS DE HEMÁCIAS PARA FINS TRANSFUSIONAIS: ESTUDOS DE VIABILIDADE CELULAR E PARÂMETROS BIOQUÍMICOS LNG Carvalho, FF Costa, MT Mesquita,Hematology, Transfusion and Cell Therapy,2024
- Photodynamic inactivation of antibiotic-resistant bacteria in whole blood using riboflavin photodynamic method L Zhu,Frontiers in microbiology,2024
- Modification of Biochemical Derangements and VEGF Secretion may Prevent Diabetic Retinopathy (DR) Mondal L K, et al,Journal of Clinical & Experimental Ophthalmology,2019
- Temporary impact of blood donation on physical performance and hematologic variables in women Stangerup I.et al,Transfusion. ,2017
- In vitro efficacy of frozen erythrocytes: implementation of new strategic blood stores to alleviate resource shortage (issue revisited). Cetinkaya RA.et al,Turk J Med Sci.,2015
Most popular with customers
-
Human Transforming Growth factor β1,TGF-β1 ELISA kit
Detect Range: 23.5 pg/ml-1500 pg/ml
Sensitivity: 5.8 pg/ml
-
-
-
Mouse Tumor necrosis factor α,TNF-α ELISA Kit
Detect Range: 7.8 pg/ml-500 pg/ml
Sensitivity: 1.95 pg/ml
-
-
-
-